ISSN 1006-3021 CN11-3474/P
Published bimonthly started in 1979
多接收等离子质谱(MC-ICP-MS )测定Mg同位素初步研究
  
关键词:MC-ICP-MS  Mg isotope
基金项目:本文由国家自然科学基金重项目(编号40331005)和国家自然科学基金面上项目(编号40473039)资助
作者单位E-mail
何学贤 国土资源部同位素地质重点实验室,中国地质科学院地质研究所北京100037 hexuexian@cags.net.cn 
朱祥坤 国土资源部同位素地质重点实验室,中国地质科学院地质研究所北京100037  
杨淳 国土资源部同位素地质重点实验室,中国地质科学院地质研究所北京100037  
唐索寒 国土资源部同位素地质重点实验室,中国地质科学院地质研究所北京100037  
摘要点击次数: 3000
全文下载次数: 2411
摘要:
Primary Study on High-precision Measurement of Magnesium Isotopes Using MC-ICP-MS
      A method for Mg isotope measurements using MC-ICPMS has been established. Using "sample-standard" bracketing technique, we tried to analyze magnesium isotopes by MC-ICP-MS on high-precision for SRM980, Aldrich, Romil and GSB materials. We discussed concentration effect and matrix effect on Mg measurement, aim to decrease interferences as possible. Relative to SRM980, we got: Aldrich (2.64±0.15)‰ (2σ) for δ26Mg and (1.34±0.09)‰ (2σ) for δ25Mg; Romil (2.46±0.15) ‰ (2σ) for δ26Mg and (1.27±0.08)‰ (2σ) for δ25Mg;Laboratory standard GSB (Laboratory of Isotope Geology, MLG) (4.05±0.03)‰ (2σ) for δ26Mg and (2.05±0.03)‰ (2σ) for δ25Mg.
He Xuexian,Zhu Xiangkun,Yang Chun,Tang Suohan.2005.Primary Study on High-precision Measurement of Magnesium Isotopes Using MC-ICP-MS[J].Acta Geoscientica Sinica,26(z1):15-18.